Cirronet CR-SEB/X Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě Cirronet CR-SEB/X. Cirronet CR-SEB/X User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - CR-SEB & CR-SEB/X

CR-SEB & CR-SEB/X Wireless Ethernet Bridge User’s Manual 5375 Oakbrook Parkway Norcross, Georgia 30093 www.cirronet.com (678) 684-2000

Strany 2

CR-SEB CR-SEBX Figure 2 shows the various connectors and LEDs of the CR-SEBX. Figure 3 illustrates the remote radio assembly. Connection between the C

Strany 3 - Declaration of Conformity

CR-SEB Figure 4. Remote Radio Assembly Note that the remote radio assembly should be mounted on a tower or building top oriented as in Figure 4. It i

Strany 4 - WARNING!!

CR-SEB Status Indicators The PWR indicator on the front panel indicates that power is applied to the CR-SEBX. The CR-SEBX does not have a power switch

Strany 5 - Table of Contents

CR-SEB Configuring the CR-SEB The network that the CR-SEB is connected to must be compatible with 10/100BaseT products. Before connecting a default c

Strany 6 - Introduction

CR-SEB Open IP Hunter by double-clicking on the file iphunter.exe on the CR-SEB CD. The following screen will appear. Click on the Search button to

Strany 7 - Getting Started

CR-SEB Double-clicking on a device with an IP address of 0.0.0.0 will bring up the following dialog box. Enter the desired IP address and the default

Strany 8 - Connectors

CR-SEB HTML Setup Once an address has been assigned, double-click on the IP number to launch an HTML setup session in a browser window. The login scre

Strany 9

CR-SEB System Status This dialog shows the Mode (Master or Slave) and Link (Up/Down) status of each device. (Clicking on Refresh should be used whe

Strany 10 - CR-SEBX

CR-SEB Radio Settings This dialog identifies the radio and current operating mode. It also allows the user to configure radio parameters for the Ne

Strany 11

CR-SEB Clicking on Enable IP address control and then Apply brings up the dialog below. Enable IP address Control This dialog is used to designate th

Strany 12

Important Regulatory Information Cirronet Product FCC ID: HSW-2410 IC 4492A-2410 Note: This unit has been tested and found to comply with t

Strany 13 - IP Hunter Utility

CR-SEB A telnet window will open up. The first line is the version of the CR-SEB firmware followed by the prompt: SEM> If the CR-SEB is to transmit

Strany 14

CR-SEB CR-SEB Operation Overview CR-SEB devices are wireless Ethernet modems that perform bridging functions in point-to-point or point-to-multipoint

Strany 15

CR-SEB When a master CR-SEB is powered on, it becomes active immediately, even if no slave CR-SEBs are detected. It will attempt to send packets addre

Strany 16 - HTML Setup

CR-SEB used to distinguish between networks of CR-SEBs and to prevent interference between the CR-SEB networks. If the master CR-SEBs are not located

Strany 17

CR-SEB CR-SEB Command Set The CR-SEB supports a series of commands that allow for configuring the Ethernet interface as well as the radio parameters o

Strany 18

CR-SEB default Resets CR-SEB configuration parameters to factory default settings. This command does not reset the radio parameters. Use the radio de

Strany 19 - Console Port

CR-SEB Bridge Commands Command Description help Displays help screen for command access <accesscode> Sets access code to allow slave CR-SEB on

Strany 20

CR-SEB CR-SEB Security Commands Command Description access help console [enable|disable] ip [help add <ipaddr> delete <

Strany 21 - CR-SEB Operation

CR-SEB Radio Commands Command Description hop [help fcc [enable|disable] length <hoplen> sequence [75|25] set <pattern> (Master only)

Strany 22 - Point-to-Multipoint Mode

CR-SEB msec and is the default. 5 is the minimum value and 24 is the maximum value. The dwell time is changed to optimize the data throughput for a gi

Strany 23

Declaration of Conformity Warning! The RLAN transceiver within this device uses a band of frequencies that are not completely harmonized within the

Strany 24 - CR-SEB Command Set

CR-SEB The following commands are issued by typing radio and then the subcommand followed by the subcommand parameters if any. Command Description hel

Strany 25

CR-SEB maxslaves slave CR-SEBs attempt to connect to the access point, they will be denied access. network The radio in the CR-SEB has 64 preprogra

Strany 26 - Radio Commands for

CR-SEB Specifications Model CR-SEB CR-SEBX Data Throughput 400Kbps Total over-the-air bandwidth 460.8Kbps Network Interface 10/100BaseT CR-SEB Networ

Strany 27 - CR-SEB Security Commands

CR-SEB Troubleshooting Ethernet Link LED is not on. Check the power LED on the CR-SEB. Check the Ethernet cable, making sure that it is fully conne

Strany 28 - Radio Commands

CR-SEB  2000- 2004 Cirronet Inc 28 M-2410-0025 Rev A Warranty Seller warrants solely to Buyer that the goods delivered hereunder shall be free fro

Strany 29

WARNING!! ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ For our Customers who wish to use this product in hazardous locations. This CR-SEB, CR-SEBX ha

Strany 30

Table of Contents Introduction ...

Strany 31

CR-SEB Introduction The CR-SEB family of products from Cirronet Incorporated provides wireless Ethernet connectivity between networks located more th

Strany 32 - Specifications

CR-SEB Getting Started The CR-SEB family of wireless Ethernet modems is easy to install and operate. In most instances, the only installation steps wi

Strany 33 - Troubleshooting

CR-SEB CR-SEB Figure 1 identifies the various connectors and LEDs of the CR-SEB. Figure 1. CR-SEB Front Panel Diagram The RF connection on the CR-SE

Strany 34 - Warranty

CR-SEB The Console port is an RS-232 serial port that may be used to configure the CR-SEB. Connection to this port is made with the 9-pinD to RJ-11 se

Komentáře k této Příručce